  • Toolbars are the most common culprit. Go to Add/Remove Programs, remove all third-party toolbars (Google, Yahoo, etc.) from Internet Explorer and from Firefox, then try INB again. (Be aware that Java updates, and updates of many other apps, try to install 3rd-party toolbars for you.)
  • Check versions of Java and Oracle. Go to Control Panel -> Java icon, Updates tab, click Update Now. If updates are needed, restart afterwards. Under Add/Remove Programs, remove all instances of Oracle JInitiator; then re-install by installing the ActiveX control on the Production site.
  • Try it on Firefox 3 if IE still doesn't work. firefox.com to install. When you go to INB -> Production in Firefox, it won't be able to find the plugin automatically; click "Manual Install" and it should bring you to the install page.
  • This site has some helpful hints, too: http://ucis.dal.ca/services/other_services/admin/support/pc_standards.html#crash

Unable to use "Extract Data No Key" function

This bug only happens in Internet Explorer. *.middlebury.edu needs to be added to trusted sites.

BannerWeb

Forgotten PIN As long as a user's access has not been disabled by trying the wrong PIN too many times, a user can reset his PIN using the "Forgot PIN?" button at http://go.middlebury.edu/bannerweb. He'll need to answer the security question he (should have) set up.

Lockouts A user who enters the wrong PIN in too many times is locked out of his account permanently until he comes to us to get his PIN reset.

Viewing Grant Budget Data In BannerWeb

This document is accessible on the following page: http://www.middlebury.edu/academics/lis/help/helpdesk/documentation/banner/finance/rd_bannerweb_fac_grants.htm

Tracking details: Author: Linda Knutson Revised: 12/18/2007

Information for Faculty on Using BannerWeb

Link to information for faculty on how to use BannerWeb (created by the Registrar's Office):

http://www.middlebury.edu/NR/rdonlyres/39CDCD05-B226-4C64-9E84-520D6DBC6415/0/BannerWeb_Faculty.pdf

Tracking details:

Author: Petar Mitrevski

Revised: 7/25/2008

How do I reset my BannerWeb PIN?

If you forgot your BannerWeb PIN, go to BannerWeb: http://go.middlebury.edu/banner enter in your 8-digit ID number and click "Forgot PIN". This option is only valid if you have created a security question. You will be prompted to answer your security question, if you do so correctly, you will be asked to create a new PIN. If you do not have a security question, or you cannot answer it correctly, you'll have to contact the Helpdesk (x2200) to have them reset your BannerWeb PIN.

Note

BannerWeb (not Internet Native Banner)

Tracking details: Author: P.M. Revised: 11/04/2007

Common Registration Errors in BannerWeb

Registration Errors

If there were any problems with adding courses to your schedule, a list of courses with error messages will appear. Always check the "Status" field next to each course after you "submit" to see that you are "Web Registered" or to determine the specific error.

Possible Error Messages

Major Restriction The course is restricted by a major(s) category that you do not match. Choose another course or request a waiver of the restriction from the instructor. If the instructor grants you an override of this restriction, you will still need to register for this course on-line.
Class Restriction The course is restricted by a class category that you do not match. Choose another course or request a waiver of the restriction from the instructor. If the instructor grants you an override of this restriction, you will still need to register for this course on-line.
Prerequisite Restriction You do not have the required prerequisites to take this course. Choose another course or request a waiver of the restriction from the instructor. If the instructor grants you an override of this restriction, you will still need to register for this course on-line.
Closed/xxxWaitlist The course is closed and has a waitlist. You may choose to put yourself on a waitlist for a closed course. If you are contacted when a seat opens in the course, you will need to have an Add Card signed by the instructor and bring it to the Registrars Office.
Closed/Reserved The course is closed for registration. Any seats left are reserved for the incoming First Year students.
Closed Section The course is closed for registration and no waitlist will be activated. If a student later drops this course, the first student to add during the registration period will be able to register for the course.
Link errors Enrollment in the lecture section requires registration in the lab/discussion/screening etc. as well or vice versa. Add the course again by entering the CRNs for all component parts of the course at the same time. The Link Error message means that youve tried to register for part of a course but not all of the required components. You can find the missing pieces by using the Schedule Type search option. Heres a quick reference of what to look for:

LINK ERROR: B1 REQUIRED, you need a section with the Schedule Type of Lab. B2, likely specific lecture requires a specific lab section e.g., with the same instructor. LINK ERROR: D1 REQUIRED, you need a section with the Schedule Type of Discussion. LINK ERROR: L1 REQUIRED, you need a section with the Schedule Type of Lecture. LINK ERROR: P1 REQUIRED, you need a section with the Schedule Type of Pre-Lab. LINK ERROR: S1 REQUIRED, you need a section with the Schedule Type of Screening. LINK ERROR: Y1 REQUIRED, you need a section with the Schedule Type of Drill 1. LINK ERROR: Z1 REQUIRED, you need a section with the Schedule Type of Drill 2.

Approval Required Enrollment requires permission of the instructor. Once requested, check your BannerWeb for Student page to see if granted and then return to register for the course.
College Restriction You are currently recorded as studying abroad next term. If you have changed plans, please contact the Office of Off-Campus Study. If this is not the case, notify the Registrar.
Maximum Hours Exceeded Registration is limited to 4 credits. 5th courses must be added by add card submitted to the Registrars Office as per the Handbook guidelines for taking a 5th course.
Repeat Hours Exceeded Courses may not be repeated for credit.
Time Conflict with CRNxxxxx Time conflicts are not permitted. Choose another course or re-work your schedule.
Course is not Available Course is not offered in the coming term.
Duplicate CRN You have accidentally entered the same CRN twice. Check and re-enter as necessary.

BannerWeb And NZERROR=28863

There seem to be a number of clients attempting to connect using older Netscape browsers, and getting error messages.

SYMPTOMS:

The following error appears in the BannerWeb (SSB) web server event_log:

[02/Dec/2005:03:45:29 +0000] [warning 11904] [ecid: -] SSL handshake fails NZERROR 28863


CAUSE:

Older browser with weaker encryption than web server.


SOLUTION:

Upgrade browser.


REFERENCE:

1. Oracle MetaLink Note 18962.1

Subject: Connecting Via SSL To Webcache Fails Last Revision Date: 16-JUN-2002

fact: Web Cache

fact: Netscape Communicator

· symptom: Cannot connect via SSL to webcache

· symptom: event_log contains errors

· symptom: SSL Handshake Failed NZERROR=28863

· symptom: Netscape browers earlier than version 4.75 fail

· symptom: Fails with 40 bit Export Browsers

· symptom: 128 bit browsers work

· cause: Bug 2113419: USE EXPORT VERSION NETSCAPE BROWSER CAUSES SSL HANDSHAKE FAILED.

· Any browser that uses weak security i.e <56bit will fail to connect to webcache.

· To check the level of encryption the browser supports go to http://www.fortify.net and then click SSLCHECK.

fix:

Either: Recreate the certificate with a 512bit key

Or: Upgrade all browsers to 128bit. This is the preferred option as reducing to 512bit keys is less secure and the existing browsers would still be using weak